What was found
WHILE IN HEAVY CHECK, CORROSION IN THE AFT WET AREA AT FR 85-86 UPPER SHEET AT Y=-10.748" AS MARKED. REMOVED AND REPLACED UPPER SHEET ON AFT WET AREA AT FR 85-86, REF SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HEAVY CHECK, CORROSION IN THE AFT WET AREA AT FR 85-86 UPPER SHEET AT Y=-10.748" AS MARKED. REMOVED AND REPLACED UPPER SHEET ON AFT WET AREA AT FR 85-86, REF SRM 51-40-08.