What was found
METAL SHIELD PLATE ON L2 DOOR IS LOOSE AND INHIBITS DOOR OPENING AND CLOSING. RE-SECURED L2 DOOR LINING IAW AMM 25-23-05. OPS CHECK DOOR LOCKING MECHANISM IAW 52-12-20. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
METAL SHIELD PLATE ON L2 DOOR IS LOOSE AND INHIBITS DOOR OPENING AND CLOSING. RE-SECURED L2 DOOR LINING IAW AMM 25-23-05. OPS CHECK DOOR LOCKING MECHANISM IAW 52-12-20. OPS CHECK GOOD.