What was found
WHILE IN HEAVY CHECK - CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 LT BEAM Y=-10.748" AS MARKED NEXT TO RIVET. REPLACED CENTER FUSELAGE III WET AREA 53-23 LT BEAM Y=-10.748", REF SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HEAVY CHECK - CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 LT BEAM Y=-10.748" AS MARKED NEXT TO RIVET. REPLACED CENTER FUSELAGE III WET AREA 53-23 LT BEAM Y=-10.748", REF SRM 51-40-08.