What was found
DURING HEAVY CHECK MAINTENANCE FOUND CORROSION AT HEATED DRAIN MAST FWD OF FR87 BETWEEN STR. 28R AND 27R ON ANGLES. REMOVED AND REPLACED ANGLES AT HEATED DRAIN MAST FWD OF FR87 BETWEEN ST 28R AND 27R. REF SRM 51-40-08.A/C REMAINS IN CHECK.