What was found
DURING HEAVY CHECK MAINTENANCE FOUND RH OUTBOARD FLOOR SILL HAS SEVERAL AREAS OF CORROSION AT FR 12-14. REMOVED AND REPLACED RH OUTBOARD FLOOR SILL AT FR 12-14 REF. SRM 51-40-08. A/C REMAINS IN CHECK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.