What was found
DURING HEAVY CHECK MAINTENANCE, FOUND AFT WET AREA FLOOR SUPPORT HAS CORROSION BETWEEN CENTER AND RT SHEAR PANELS AT FRAMES 87 - 88. BLENDED AND FOUND OUT OF LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK MAINTENANCE, FOUND AFT WET AREA FLOOR SUPPORT HAS CORROSION BETWEEN CENTER AND RT SHEAR PANELS AT FRAMES 87 - 88. BLENDED AND FOUND OUT OF LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-08.