What was found
DURING HEAVY CHECK - MAJOR - MISSING ALL FASTENERS IN SHEAR CLIP FRAME 22 APROX STGR 09R-10R. LOCATED, DRILLED AND INSTALLED SHEAR CLIP AT FRAME 22 APROX STGR 09R-10R REF. SRM 51-40-02, 51-40-08. RESTORED SURFACE PROTECTION TO SHEAR CLIP FRAME 22 APROX STR 09R-10R REF. SRM 51-23-06.