What was found
FOUND AFT SERVICE DOOR R2 LOWER SILL BEAM, FR 87 STR 17R, AFT GIRT BAR FITTING AREA, INNER CHORD STRAP FOUND CORRODED. REMOVED AND REPLACED INNER CHORD STRAP IAW SRM 51-43-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND AFT SERVICE DOOR R2 LOWER SILL BEAM, FR 87 STR 17R, AFT GIRT BAR FITTING AREA, INNER CHORD STRAP FOUND CORRODED. REMOVED AND REPLACED INNER CHORD STRAP IAW SRM 51-43-03.