What was found
DURING HEAVY CHECK MAINTENANCE FOUND CORRODED SHEAR CLIP @ FR 84 ST 28-29R. REMOVED AND REPLACED NEW SHEAR CLIP @ FR 84 ST 28-29R. REF: SRM 51-40-08. A/C REMAINS IN CHECK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK MAINTENANCE FOUND CORRODED SHEAR CLIP @ FR 84 ST 28-29R. REMOVED AND REPLACED NEW SHEAR CLIP @ FR 84 ST 28-29R. REF: SRM 51-40-08. A/C REMAINS IN CHECK.