What was found
WHILE IN HEAVY CHECK-AFT WET AREA RH SHEAR PANEL HAS CORROSION AREA.REMOVED AND REPLACED SHEAR PANEL REF. EMB SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HEAVY CHECK-AFT WET AREA RH SHEAR PANEL HAS CORROSION AREA.REMOVED AND REPLACED SHEAR PANEL REF. EMB SRM 51-40-08.