As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AFT WET AREA GUSSET AT FR90 LBL 10.00" AS MARKED REMOVED AND REPLACED GUSSET AT FRAME 90 REFR EMB SRM 51-21-01, SRM 51-40-08. APPLIED SURFACE PROTECTION TO NEW AFT WET AREA GUSSET AT FR90 LBL. REF: EMB SRM 51-23-06. TOPCOAT P.O. 257552