WHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA L/H SHEAR PANEL BETWEEN FR87 AND FR88 AS MARKED. REMOVED AND REPLACED AFT WET AREA RH SHEAR PANEL. REF EMB175 SRM 51-40-08