What was found
WHILE IN HEAVY CHECK FOUND CORROSION-FWD CARGO CUTOUT LOWER CLOSEOUT PANEL CORRODED AS MARKED REMOVED AND REPLACED FWD CARGO CLOSE OUT PANEL. REF EMB 175 SRM 51-40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HEAVY CHECK FOUND CORROSION-FWD CARGO CUTOUT LOWER CLOSEOUT PANEL CORRODED AS MARKED REMOVED AND REPLACED FWD CARGO CLOSE OUT PANEL. REF EMB 175 SRM 51-40-08