What was found
DURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA IN MIDDLE OF CENTER SHEAR PANEL. REMOVED AFT WET AREA CENTER SHEAR PANEL, REF. SRM 51-40-08. LOCATED, DRILLED, DEBURRED, AND ALODINED(PO#243626) NEW CENTER SHEAR PANEL, REF. SRM 51-40-02, AND SRM 51-23-04. INSTALLED A NEW CENTER SHEAR PANEL REF SRM 51-40-08.TOP COATED FASTENERS REF SRM 51-23-06. A/C REMAINS IN CHECK.