DURING HEAVY CHECK. FLOOR SUPPORT STRUCTURE CENTER SHEAR PANEL BETWEEN FR87 AND FR88 HAS CORROSION. SHEAR PANEL WAS REPLACED IAW SRM 51-42-02. AIRCRAFT REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.