As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE IN HEAVY CHECK FOUND PAINT DAMAGE AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAMS. REMOVED LOCATED AND DRILLED NEW AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAM REF SRM 51-40-02, 51-40-08 APPLIED ALODINE AREA SRM 51-23-04 PO# 243026 INSTALLED NEW AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAM REF SRM 51-40-02, 51-40-08