What was found
WHILE IN HEAVY CHECK FOUND SUPPORT ANGLE CORRODED BETWEEN FR87R & FR 86R, BETWEEN STGR 28R & STGR 27R UPON FURTHER INVESTIGATION. FOUND SUPPORT ANGLE BETWEEN FR87R & FR 86R, BETWEEN STGR 28R & STGR 27R TO BE 100% MATERIAL LOSS. CORROSION DIMENSIONS: H-100% LOSS L-.771" W-.658" NOMINAL .062" OUT OF LIMITS. REF EMB SRM 51-10-02 TOOLING TC2-50431 CAL 11-12-20 HG2-7135 CAL 10-29-20 INSTALLED NEW SUPPORT ANGLE BETWEEN FR87R & FR 86R, BETWEEN STGR 28R & STGR 27R REF SRM 51-40-08 AND RESTORED SURFACE PROTECTION REF SRM 51-23-06 AND APPLIED CIC REF CPM 51-25-00-910-001-A. PN# 170-87562-001