What was found
FWD CARGO DOOR SURROUND LOWER SILL BEAM, CORROSION FOUND ON 2 SUPPORT BRACKETS BETWEEN FR 24-26. REPLACED IAW SRM 51-41-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO DOOR SURROUND LOWER SILL BEAM, CORROSION FOUND ON 2 SUPPORT BRACKETS BETWEEN FR 24-26. REPLACED IAW SRM 51-41-01.