What was found
MAJOR REPAIR, WHILE IN HEAVY CHECK FWD FUSELAGE PAX FLOOR CROSS BEAM AT FR 17 HAS CORROSION ON UPPER SURFACE OF TOP FLANGE APPROXIMATELY LBL 4" IN-BETWEEN FLOOR SEAT TRACKS. REPAIRED PER SRM 53-00-10-R03P.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAJOR REPAIR, WHILE IN HEAVY CHECK FWD FUSELAGE PAX FLOOR CROSS BEAM AT FR 17 HAS CORROSION ON UPPER SURFACE OF TOP FLANGE APPROXIMATELY LBL 4" IN-BETWEEN FLOOR SEAT TRACKS. REPAIRED PER SRM 53-00-10-R03P.