What was found
DURING HEAVY CHECK INSPECTION CFIII, FLOOR STRUCTURE, CORROSION FOUND AT GUSSET PLATE AT FR 91 RT SIDE. GUSSET PLATE AT FR 91 RT SIDE, CRIII FLOOR STRUCTURE REPLACED, IAW ERJ 175 SRM 51-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK INSPECTION CFIII, FLOOR STRUCTURE, CORROSION FOUND AT GUSSET PLATE AT FR 91 RT SIDE. GUSSET PLATE AT FR 91 RT SIDE, CRIII FLOOR STRUCTURE REPLACED, IAW ERJ 175 SRM 51-41-02.