What was found
CORROSION FOUND ON CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE IB GUSSET PLATE AT FR 90, RHS. FLOOR SUPPORT STRUCTURE I/B GUSSET PLATE @ FR 90 R/H FOUND CORRODED HAS BEEN REMOVED AND REPLACED IAW ERJ 175 SRM 51-41-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE IB GUSSET PLATE AT FR 90, RHS. FLOOR SUPPORT STRUCTURE I/B GUSSET PLATE @ FR 90 R/H FOUND CORRODED HAS BEEN REMOVED AND REPLACED IAW ERJ 175 SRM 51-41-02