What was found
CORROSION FOUND ON CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE GUSSET PLATE AT FRAME 90 RHS. CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE GUSSET PLATE AT FRAME 90, RHS REPLACED WITH NEW PART IAW EMBRAER 175 SRM 51-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE GUSSET PLATE AT FRAME 90 RHS. CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE GUSSET PLATE AT FRAME 90, RHS REPLACED WITH NEW PART IAW EMBRAER 175 SRM 51-41-02.