What was found
SHEAR CLIP CORRODED, FR 86, STGR 28R-29R. REMOVED AND REPLACED CORRODED SHEAR CLIP AT FR86 BETWEEN STGR 28R-29R; REFER SRM 51-40-08. RE-APPLIED SURFACE PROTECTIONJ TO FASTENERS PER SRM 51-23-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR CLIP CORRODED, FR 86, STGR 28R-29R. REMOVED AND REPLACED CORRODED SHEAR CLIP AT FR86 BETWEEN STGR 28R-29R; REFER SRM 51-40-08. RE-APPLIED SURFACE PROTECTIONJ TO FASTENERS PER SRM 51-23-06.