What was found
CORROSION FOUND ON CENTER FUSELAGE III, FLOOR SUPPORT STRUCTURE L/H SHEAR PANEL AT FR 87-88. CENTER FUSELAGE III FLOOR STRUCTUREL/H SHEAR PLATE HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER SRM 51-42-01 AND 51-43-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON CENTER FUSELAGE III, FLOOR SUPPORT STRUCTURE L/H SHEAR PANEL AT FR 87-88. CENTER FUSELAGE III FLOOR STRUCTUREL/H SHEAR PLATE HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER SRM 51-42-01 AND 51-43-01