What was found
CORROSION FOUND ON CENTER FUSELAGE III, FLOOR SUPPORT STRUCTURE MID SHEAR PANEL AT FR 87-88. CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE MID SHEAR PANEL AT FR 87-88 HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER SRM 51-42-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON CENTER FUSELAGE III, FLOOR SUPPORT STRUCTURE MID SHEAR PANEL AT FR 87-88. CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE MID SHEAR PANEL AT FR 87-88 HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER SRM 51-42-01