What was found
DURING HEAVY CHECK MAINTENANCE FOUND AFT FUSELAGE III FLOOR STRUCTURE MID SHEAR PANEL BETWEEN FR87 AND FR88, LBL 10 TO RBL 10 CORRODED. MID SHEAR PANELBETWEEN FR87 AND FR88, LBL 10 TO RBL 10 REPLACED WITH NEW IAW EMB 170 SRM 51-42-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK MAINTENANCE FOUND AFT FUSELAGE III FLOOR STRUCTURE MID SHEAR PANEL BETWEEN FR87 AND FR88, LBL 10 TO RBL 10 CORRODED. MID SHEAR PANELBETWEEN FR87 AND FR88, LBL 10 TO RBL 10 REPLACED WITH NEW IAW EMB 170 SRM 51-42-01.