What was found
FRAME 9 STR 11L CRACKED SHEAR CLIP UNDER LH D.V. WINDOW. INSTALLED NEW SHEAR CLIP AT FRAME 9 STR 11L UNDER LH D.V. WINDOW. REF SRM 51-- 40-08. COMPLIED WITH SURFACE PROTECTION AS REQUIRED. REF SRM 51-23-06. MAJOR REPAIR
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 9 STR 11L CRACKED SHEAR CLIP UNDER LH D.V. WINDOW. INSTALLED NEW SHEAR CLIP AT FRAME 9 STR 11L UNDER LH D.V. WINDOW. REF SRM 51-- 40-08. COMPLIED WITH SURFACE PROTECTION AS REQUIRED. REF SRM 51-23-06. MAJOR REPAIR