What was found
CORROSION SHEAR CLIP FRAME 88, STRINGER 25R-26R. REMOVED AND REPLACED SHEAR CLIP AT FRAME 88 BETWEEN STGR 25R-26R REFER SRM 51-40-08. RESTORED SURFACE PROTECTION TO FASTENERS PER SRM 51-23-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION SHEAR CLIP FRAME 88, STRINGER 25R-26R. REMOVED AND REPLACED SHEAR CLIP AT FRAME 88 BETWEEN STGR 25R-26R REFER SRM 51-40-08. RESTORED SURFACE PROTECTION TO FASTENERS PER SRM 51-23-06.