What was found
FOUNF CORROSION ON FWD CARGO DOOR CUTOUT LOWER BEAM AT AFT FITTING MOUNT HOLES,BETWEEN FRA 24 TO 27 AND AT STR 26R. REMOVED AND REPLACED LOWER BEAM IAW EMB SRM 51-43-03 AND 51-40-02. ALSO REF VP-054991-2022 N/R #1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUNF CORROSION ON FWD CARGO DOOR CUTOUT LOWER BEAM AT AFT FITTING MOUNT HOLES,BETWEEN FRA 24 TO 27 AND AT STR 26R. REMOVED AND REPLACED LOWER BEAM IAW EMB SRM 51-43-03 AND 51-40-02. ALSO REF VP-054991-2022 N/R #1.