What was found
SHEER CLIP AT FRAME 87 BETWEEN STRINGERS 28R-27R HAS CORROSION. REMOVED AND REPLACED SHEAR CLIP AT FR87 BETWEEN STGR 28R-27R REFER SRM 51-40-08 AND RESTORED SURFACE PROTECTION TO REWORKED AREA REFER SRM 51-23-06, CPM 51-25-00
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEER CLIP AT FRAME 87 BETWEEN STRINGERS 28R-27R HAS CORROSION. REMOVED AND REPLACED SHEAR CLIP AT FR87 BETWEEN STGR 28R-27R REFER SRM 51-40-08 AND RESTORED SURFACE PROTECTION TO REWORKED AREA REFER SRM 51-23-06, CPM 51-25-00