As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE WORKING SHEER CLIP AT FRAME 87 BETWEEN STRINGERS 28R--27R. DRILL START FOUND AT STGR 27 LOWER FLANGE RADIUS BETWEEN FR 86-87. PERFORMED STRINGER SPLICE REPAIR TO STGR 27R AT FRAME 87 REFER ETD2023-170-021497. RESTORED SURFACE PROTECTION TO REWORKED AREA PER SRM 51-23-06, CPM 51-25-00.