What was found
DURING HEAVY CHECK MAINTENANCE FOUND FLOOR STRUCTURE RH PANEL SUPPORT CORRODED AT FR88 RH TO FR90 RH, RBL 36. CORRODED SUPPORT PANEL RH AT FR 88-90RH RBL36 FLOOR STRUCTURE REMOVED AND REPLACED IAW SRM 51-43-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK MAINTENANCE FOUND FLOOR STRUCTURE RH PANEL SUPPORT CORRODED AT FR88 RH TO FR90 RH, RBL 36. CORRODED SUPPORT PANEL RH AT FR 88-90RH RBL36 FLOOR STRUCTURE REMOVED AND REPLACED IAW SRM 51-43-01.