What was found
AFT FUSELAGE BELOW FLOOR STGR-23L HAS CORROSION BETWEEN FR-89 AND 90. REMOVED AND REPLACED STGR 23L FROM FR73-FR90 REF EMB SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT FUSELAGE BELOW FLOOR STGR-23L HAS CORROSION BETWEEN FR-89 AND 90. REMOVED AND REPLACED STGR 23L FROM FR73-FR90 REF EMB SRM 51-40-08.