What was found
DURING HEAVY MAINT CHECK FOUND CORRODED SHEAR CLIP, FRAME 74, STRINGERS 28R-29R. REMOVED AND REPLACED SHEAR CLIP AT FR 74 BETWEEN STGR 28R-29R. REF EMB SRM51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINT CHECK FOUND CORRODED SHEAR CLIP, FRAME 74, STRINGERS 28R-29R. REMOVED AND REPLACED SHEAR CLIP AT FR 74 BETWEEN STGR 28R-29R. REF EMB SRM51-40-08.