What was found
DURING HEAVY CHECK FOUND CF III FLOOR STRUCTURE FOUND CORRODED RIVETS (QTY14) ON FR 87 AT LH AND MID SHEAR PANEL. REMOVED AND REPLACED RIVETS L/H AND MID SHEAR PANEL AT FR87 IAW SRM 51-42-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK FOUND CF III FLOOR STRUCTURE FOUND CORRODED RIVETS (QTY14) ON FR 87 AT LH AND MID SHEAR PANEL. REMOVED AND REPLACED RIVETS L/H AND MID SHEAR PANEL AT FR87 IAW SRM 51-42-01