What was found
DURING HEAVY CHECK CF III FR 87-88 RBL 50 FOUND CORRODED FLOOR SUPPORT SPLICE. REMOVED AND REPLACED CORRODED FLOOR SUPPORT SPLICE IAW EMB 170/175 SRM 51-42-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK CF III FR 87-88 RBL 50 FOUND CORRODED FLOOR SUPPORT SPLICE. REMOVED AND REPLACED CORRODED FLOOR SUPPORT SPLICE IAW EMB 170/175 SRM 51-42-02