DURING HEAVY CHECK CORRODED FLOOR PANEL SUPPORT ANGLE FOUND ON FWD FUSELAGE CROSSBEAM AT FR 14 RBL 29. REMOVED AND REPLACED SUPPORT ANGLE ON FWD FUSELAGE CROSSBEAM IAW EMB 170/175 SRM 51-40-08