What was found
DURING HEAVY CHECK CORRODED FLOOR SUPPORT FITTING FOUND AT FWD WET AREA FR 16 LBL 45. REMOVED AND REPLACED FWD WET AREA SUPPORT FITTING IAW EMB 170/175 SRM 51-46-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK CORRODED FLOOR SUPPORT FITTING FOUND AT FWD WET AREA FR 16 LBL 45. REMOVED AND REPLACED FWD WET AREA SUPPORT FITTING IAW EMB 170/175 SRM 51-46-01