DURING HEAVY CHECK CORRODED FLOOR SUPPORT FITTING AT FWD WET AREA FR 19 LBL 45. REMOVED AND REPLACED SUPPORT FITTING FR 19 LBL45 IAW EMB 170/175 SRM 51-40-08