What was found
FWD FUSELAGE DENTED AND GOUGED BETWEEN FRA 19-20 AND STR14R-15R. REPLACED SHEAR CLIP AT FRA 19 AND BETWEEN STR 14R-15R IAW EMB 170/175 SRM 51-41-01 AND 51-41-02 ALSO REF ETD2025-170-923116 AND VP-025441-2025 FOR WORK ACCOMPLISHED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD FUSELAGE DENTED AND GOUGED BETWEEN FRA 19-20 AND STR14R-15R. REPLACED SHEAR CLIP AT FRA 19 AND BETWEEN STR 14R-15R IAW EMB 170/175 SRM 51-41-01 AND 51-41-02 ALSO REF ETD2025-170-923116 AND VP-025441-2025 FOR WORK ACCOMPLISHED.