What was found
DURING HEAVY CHECK FOUND WET AREA RH O/B FLOOR SPLICE CORRODED FR 87-88. SPLICE WAS REPLACED IAW SRM 51-42-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK FOUND WET AREA RH O/B FLOOR SPLICE CORRODED FR 87-88. SPLICE WAS REPLACED IAW SRM 51-42-02