What was found
EVALUATED 14EA SPOT OF CORROSION ON COCKPIT COPILOT'S FLOOR DOUBLER AS MARKED AND REMOVED DAMAGE BY BLENDING. DEEPEST MEASURED(LOCATED BETWEEN FR 9-8): L=6.1", W=1", MATERIAL LOSS= 0.015", ORIGINAL THICKNESS= 0.040", MAX. ALLOWABLE MATERIAL LOSS= 0.008"(20%), REMAINING THICKNESS= 0.025". DAMAGE FOUND TO BE OUT OF LIMITS. REF SRM 53-10-10/AD04.