Service difficulty report · Floorbeam · Emb ERJ170200LR

Difficulty date
January 5, 2026
Submitted
January 5, 2026
Operation
Air carrier
Aircraft
N135HQ
Make and model
Emb ERJ170200LR
Aircraft serial
17000224
Aircraft time
43,518 hours, 32,986 cycles
Part
Floorbeam
Condition
Corroded
Location
Zone 200
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EVALUATED 14EA SPOT OF CORROSION ON COCKPIT COPILOT'S FLOOR DOUBLER AS MARKED AND REMOVED DAMAGE BY BLENDING. DEEPEST MEASURED(LOCATED BETWEEN FR 9-8): L=6.1", W=1", MATERIAL LOSS= 0.015", ORIGINAL THICKNESS= 0.040", MAX. ALLOWABLE MATERIAL LOSS= 0.008"(20%), REMAINING THICKNESS= 0.025". DAMAGE FOUND TO BE OUT OF LIMITS. REF SRM 53-10-10/AD04.

More about the Emb ERJ 170-200 LR