DURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE BETWEEN FR 87- 88 L/H SHEAR PANEL FOUND WITH CORROSION. REMOVED AND REPLACED SHEAR PANEL IAW EMB 170/175 SRM 51-42-01 AND 51-42-02