What was found
DURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE BETWEEN FR 87-88 MIDDLE SHEAR PANEL FOUND WITH CORROSION. REMOVED AND REPLACED SHEAR PANEL IAW EMB 170/175 SRM 51-42-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE BETWEEN FR 87-88 MIDDLE SHEAR PANEL FOUND WITH CORROSION. REMOVED AND REPLACED SHEAR PANEL IAW EMB 170/175 SRM 51-42-01.