What was found
DURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE FR 84 AND RBL35TO 45 PANEL SUPPORT FOUND WITH CORROSION. REMOVED AND REPLACED PANEL SUPPORT IAW SRM 51-41-01 AND 51-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE FR 84 AND RBL35TO 45 PANEL SUPPORT FOUND WITH CORROSION. REMOVED AND REPLACED PANEL SUPPORT IAW SRM 51-41-01 AND 51-41-02.