What was found
DURING SCHEDULED C1 CHECK, FOUND AFT CARGO COMPARTMENT FLOOR SUPPORT RBL 24 Z-ANGLE HOLED AT BS 1130 AND CORROSION BLENDOUT BEYOND LIMITS AT BS 1050. REPLACED Z-ANGLE FROM BS 1044 TO 1140 PER SRM 51-40-4 FIG 1, SHEET 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C1 CHECK, FOUND AFT CARGO COMPARTMENT FLOOR SUPPORT RBL 24 Z-ANGLE HOLED AT BS 1130 AND CORROSION BLENDOUT BEYOND LIMITS AT BS 1050. REPLACED Z-ANGLE FROM BS 1044 TO 1140 PER SRM 51-40-4 FIG 1, SHEET 5.