What was found
DURING SCHEDULED S4 STRUCTURAL/CPCP INSPECTION PER CARD S4 14111, FOUND STR 16L SPLICE CORRODED AT BS 848. REPAIRED PER SRM 53-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED S4 STRUCTURAL/CPCP INSPECTION PER CARD S4 14111, FOUND STR 16L SPLICE CORRODED AT BS 848. REPAIRED PER SRM 53-10-3.