What was found
DURING SCHEDULED S3 INSPECTION PER CARD S3-53102, FOUND STR 24L END SPLICE CORRODED AT BS 740. REPLACED STRINGER END SPLICE PER SRM 51-10-1 AND 53-10-3 M-54 NR 094.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED S3 INSPECTION PER CARD S3-53102, FOUND STR 24L END SPLICE CORRODED AT BS 740. REPLACED STRINGER END SPLICE PER SRM 51-10-1 AND 53-10-3 M-54 NR 094.