What was found
DURING SCHEDULED S6 INSPECTION PER CARD PER CARD S6-51103, FOUND BS 380 FRAME CORRODED AT STR 26R TO 28R. REPAIRED PER SRM 53-10-4, FIG 12. M-54 NR 206.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED S6 INSPECTION PER CARD PER CARD S6-51103, FOUND BS 380 FRAME CORRODED AT STR 26R TO 28R. REPAIRED PER SRM 53-10-4, FIG 12. M-54 NR 206.