What was found
DURING SCHEDULED S6 INSPECTION PER CARD S6-51103, FOUND STR 25R CORRODED AT BS 360 TO 380. REPLACED STRINGER SECTION PER SRM 51-10-1. M-54 NR 211.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED S6 INSPECTION PER CARD S6-51103, FOUND STR 25R CORRODED AT BS 360 TO 380. REPLACED STRINGER SECTION PER SRM 51-10-1. M-54 NR 211.